 General Purpose Power Relays
MKS-X
MK-S-series Relays with AC and DC Load switching Models
* Models for DC Loads can switch 220 VDC, 10 A (resistive). * Models for AC Loads can switch 250 VAC, 15 A (resistive). * Lineup includes models with 1FormA and 1FormA+1FormB contact arrangements. * Models available with operation indicators and built-in test buttons. * Standards: UL/CSA, IEC (TUV certification) * RoHS compliant.
Ordering Information
List of Models
Models for DC Loads Contact form Type Standard Built-in Operation Indicators Test Button SPST-NO Model MKS1XT-10 MKS1XTN-10 MKS1XTI-10 SPST-NO/SPST-NC Model MKS2XT-11 MKS2XTN-11 MKS2XTI-11 MKS2XTIN-11 Models for AC Loads SPST-NO Model MKS1T-10 MKS1TN-10 MKS1TI-10 MKS1TIN-10 SPST-NO/SPST-NC Model MKS2T-11 MKS2TN-11 MKS2TI-11 MKS2TIN-11
Test Button and Built-in Operation Indicators MKS1XTIN-10
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications. Example: MKS2XTIN-11 AC240 Rated voltage 2. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.
Accessory (Order Separately)
Connecting Socket and Hold-down Clips
Classifications Back-connecting Socket Front-connecting Socket PCB Mount DIN Track or Panel Mount Built-in diode No No Yes Socket P7M-06P P7MF-06 P7MF-06-D PYC-A2 Hold-down Clip
Note: 1. The P7M-06P, P7MF-06, and P7MF-06-D can be used with models for DC loads with an SPST-NO or SPST-NO/SPST-NC contact form or with models for AC loads with an SPST-NO or SPST-NO/SPST-NC contact form. 2. The P7MF-06-D has a built-in diode and can thus be used only with Relays with DC operating coils. Do not use it with a Relay with an AC operating coil. 3. Refer to Gang Mounting in the Safety Precautions section for the conditions required to gang mounti multiple relays side-by-side. 4. Use the Clips to securely mount the Relay and prevent it from falling due to vibration or shock.
General Purpose Power Relays
MKS-X
1
Specifications
Contact Ratings
Models for DC Loads
Contact form Model Load Item Contact configuration Contact material Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity (reference value) NO NC NO NC NO NC NO NC NO NC 2,200 W 10 A, 220 VDC NO NC Resistive load SPST-NO MKS1XT(I)(N)-10 Inductive load L/R = 7 ms Double-break --AgSnIn 5 A, 220 VDC --10 A --220 VDC --10 A --------1,100 W 440 W 5A 2A --------0.4 A, 220 VDC 5 A, 220 VDC 2 A, 220 VDC DC13 class Resistive load SPST-NO/SPST-NC MKS2XT(I)(N)-11 Inductive load L/R = 7 ms Double-break Single-break AgSnIn 3 A, 220 VDC 5A 2A 220 VDC 0.2 A, 220 VDC 0.3 A, 220 VDC 0.1 A, 220 VDC DC13 class
Note: 1. If the L/R of an inductive load exceeds 7 ms with a Model for a DC Load, the arc interruption time must be less than approximately 50 ms to use the Relay. Design the circuit so that the arc interruption time is 50 ms or less. 2. These values apply to a switching frequency of 30 times per minute.
Models for AC Loads
Contact form Model Load Item Contact configuration Contact material Rated load Rated carry current Max. switching voltage Max. switching current Max. switching capacity (reference value) NO NC NO NC NO NC NO NC NO NC NO NC SPST-NO MKS1T(I)(N)-10 Resistive load Double-break --AgSnIn 15 A, 250 VAC --15 A --250 VAC --15 A --3,750 VA --15 A 5A 3,750 VA 1,250 VA SPST-NO/SPST-NC MKS2T(I)(N)-11 Resistive load Double-break Single-break AgSnIn 15 A, 250 VAC 5 A, 250 VAC 15 A 5A 250 VAC
Note: These values apply to a switching frequency of 20 times per minute.
2
General Purpose Power Relays
MKS-X
Coil Ratings
Item Rated current (mA) Rated voltage (V) AC 24 100 110 120 200 220 230 240 DC 12 24 48 110 220 50 Hz 110 26.6 24.2 22.2 13.3 12.1 11.5 11.0 126 63.2 32.0 13.6 6.8 60 Hz 96.3 23.1 21.0 19.3 11.6 10.5 10.0 9.6 Coil resistance () 48.4 760 932 1,130 3,160 3,550 4,250 4,480 95 380 1,500 8,060 32,200 15% min. of rated voltage Approx. 1.5 W Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (VA, W) Approx. 2.3 VA at 60 Hz Approx. 2.7 VA at 50 Hz 80% max. of rated 30% min. of rated 110% of rated voltage voltage at 60 Hz voltage 25% min. of rated voltage at 50 Hz
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/-20% for AC rated current and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. The Maximum Voltage is the highest voltage that can be applied to the coil temporarily, not continuously. 4. The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils).
Characteristics
Contact resistance (See note 2) Operate time (See note 3) Release time (See note 3) Max. operating frequency Mechanical Electrical Insulation resistance (See note 4) Dielectric strength 100 m max. AC: 20 ms max. DC: 30 ms max. 20 ms max. 18,000 operations/h Models for DC loads: 1,800 times/hour Models for AC loads: 1,200 times/hour 100 M min. 2,500 VAC 50/60 Hz for 1 min. between coil and contacts 2,500 VAC 50/60 Hz for 1 min. between contacts of different polarity 1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity Vibration resistance Shock resistance Destruction: Malfunction: Destruction: Malfunction Life expectancy Mechanical 10 to 55 Hz, 1.0-mm double amplitude 10 to 55 Hz, 1.5-mm double amplitude 1,000 m/s2 when relay is properly mounted into P7M-06P PCB socket 500m/s2 when relay is properly mounted into P7MF-06(-D) socket 100 m/s2
1,000,000 operations min. (at 18,000 operations/hr) 10 mA at 24 VDC -40C to 60C (with no icing or condensation) Note: The range is -25C to 60C for models with built-in operation indicators. 5% to 85% SPST-NO: Approx. 73 g, SPST-NO/SPST-NC: Approx. 82 g
Electrical (See note 5) 100,000 operations min. (at rated load and maximum switching frequency) Minimum permissible load (Reference value. See note 6) Ambient operating temperature Ambient operating humidity Weight Note: 1. 2. 3. 4.
The values given above are initial values. The contact resistance was measured for 1 A at 5 VDC using the voltage drop method. The operate time was measured with the rated voltage imposed and any contact bounce ignored at an ambient temperature of 23C. The insulation resistance was measured with a 500-VDC insulation resistance tester at the same places as those used for checking the dielectric strength. 5. The electrical endurance was measured at an ambient temperature of 23C. 6. P level: 60=0.1 x 10-6/operations
General Purpose Power Relays
MKS-X
3
Approved Standards
UL Recognized CSA Certified
Model MKS1XT@-@ Coil ratings 12 to 220 VDC 24 to 240 VAC Contact ratings 10 A, 220 VDC (Resistive) NO contacts 5 A, 220 VDC L/R (T0.632) = 7 ms 0.4 A, 220 VDC L/R (T0.95) = 300 ms 5 A, 220 VDC (Resistive) NO contacts 3 A, 220 VDC L/R (T0.632) = 7 ms 0.2 A, 220 VDC L/R (T0.95) = 300 ms 2 A, 220 VDC (Resistive) NC contacts 0.3 A, 220 VDC L/R (T0.632) = 7 ms 0.1 A, 220 VDC L/R (T0.95) = 300 ms NO contacts 15 A, 250 VAC (Resistive) NO contacts 15 A, 250 VAC (Resistive) NC contacts 5 A, 250 VAC (Resistive) Operations 6,000
MKS2XT@-@
MKS1T@-@ MKS2T@-@
IEC Standard/TUV Certification: IEC61810-1 (Certification No. R50104853)
Model MKS1XT@-@ Coil ratings 12, 24, 48, 110, 220 VDC 24, 100, 110, 120, 200, 220, 230, 240 VAC Contact ratings DC-1: 10 A, 220 VDC NO contacts 5 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.4 A, 220 VDC DC-1: 5 A, 220 VDC NO contacts 3 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.2 A, 220 VDC DC-1: 2 A, 220 VDC NC contacts 0.3 A, 220 VDC L/R (T0.632) = 7 ms DC-13: 0.1 A, 220 VDC NO contacts AC-1: 15 A, 250 VAC 50/60 Hz NO contacts AC-1: 15 A, 250 VAC 50/60 Hz NC contacts AC-1: 5 A, 250 VAC 50/60 Hz Operations 100,000
MKS2XT@-@
MKS1T@-@ MKS2T@-@
4
General Purpose Power Relays
MKS-X
Engineering Data
Maximum Switching Power
MKS1XT@-10
Switching current (A)
100 DC resistive load 10 5 DC inductive load L/R = 7 ms
MKS2XT@-11
Switching current (A)
100 DC resistive load NO 10 5 3 2 1 0.3 0.2 DC resistive load L/R = 7 ms NO
1 0.4
DC resistive load L/R = 7 ms NC
DC resistive load NC
0.1
DC inductive load DC13 class
0.1 DC resistive load DC13 class NO 0.01 100 1.000 1 10 DC resistive load DC13 class NC 100 1.000
0.01 1 10
Switching voltage (V)
Switching voltage (V)
MKS1T@-10
Switching current (A)
100
MKS2T@-11
Switching current (A)
100 AC resistive load NO 15 10 5 AC resistive load NC
15 10 AC resistive load 1
1
0.1
0.1
0.01 1 10 100 1.000
0.01 1 10 100 1.000
Switching voltage (V)
Switching voltage (V)
Ambient Temperature vs. Pick-up and Drop out Voltage
MKS2XT-11 AC Specification (60 Hz)
Must operate/release voltage (%)
100
MKS2XT-11
DC Specification
Must operate/release voltage (%)
100
Number of Relays: 5
80
Must operate voltage Must release voltage
Number of Relays: 5
80
Must operate voltage Must release voltage
60
60
40
40
20
20
-40
23
60
-40
23
60
Ambient temperature (C)
Ambient temperature (C)
Inductive Load Switching Power (Models for DC Loads)
MKS1XT@-10
Switching current (A)
100 220 VDC
MKS2XT@-11
Switching current (A)
10 220 VDC
10
1
NO
1
0.1 NC
0.1 0 7 10 50 100
0.01 0 7 10 50 100
Load time constant (ms)
Load time constant (ms)
General Purpose Power Relays
MKS-X
5
Dimensions
Models for DC Loads
Standard Models
MKS1XT-10 MKS2XT-11
34.5 max.
(Unit: mm)
Models with Built-in Operation Indicators
MKS1XTN-10 MKS2XTN-11
0.8 34.5 max.
Models for AC Loads
Standard Models
MKS1T-10 MKS2T-11
44 max.
Models with Built-in Operation Indicators
MKS1TN-10 MKS2TN-11
7.3
Models for DC Loads
Models with Test Button
MKS1XTI-10 MKS2XTI-11
3.5
34.5 max.
Models with Test Button and Built-in Operation Indicators
MKS1XTIN-10 MKS2XTIN-11
0.8 34.5 max.
Models for AC Loads
Models with Test Button
MKS1TI-10 MKS2TI-11
0.5
44 max.
Models with Test Button and Built-in Operation Indicators
MKS1TIN-10 MKS2TIN-11
7.3
29.7
Terminal Arrangement and Internal Connection (Bottom View)
MKS1XT-10 MKS1XTI-10 MKS1XTN-10 MKS1XTIN-10 DC specification AC specification MKS2XT-11 MKS2XTI-11 MKS2XTN-11 MKS2XTIN-11 DC specification AC specification
2 4 8 A (+) 6 (+) 4 8 6 (+) 4 8 B (-) 6 (+) 4
2 4
2
4 8 (+)
6 (+)
6 (+) 8 (+)
6 (+) 8 (+)
A
MKS1T-10 MKS1TI-10
B
A
B
A
MKS2T-11 MKS2TI-11
B
A (+)
B (-)
A
B
MKS1TN-10 MKS1TIN-10 DC specification AC specification
MKS2TN-11 MKS2TIN-11 DC specification AC specification
2 4 8 6 4 8 B (-) 6 4
2
2 6
4 8
6
4 8
6
4 8
6
8
A
B
A (+)
A
B
A
B
A (+)
B (-)
A
B
Note: 1. Wire properly using the correct coil polarity. 2. The contact terminals on Models for DC Loads have polarity. Wire properly using the correct polarity.
6
General Purpose Power Relays
MKS-X
Connecting Socket
Back-connecting Socket
P7M-06P
Dimensions
39 max.
Terminal Arrangement/Internal Connections PCB Mounting Holes (Bottom View) (Bottom View)
2 4
43 max. 39 max.
6
0.9 8.3 7.7
5.5
8 A B
11.05 11.05
21.9
4.35 22.1
0.9 8.3 5.5
7.7
Front-connecting Socket
P7MF-06 P7MF-06-D
Dimensions
7 34 max.
Terminal Arrangement/Internal Connections (TOP View)
P7MF-06 P7MF-06-D
Mounting Holes (TOP View)
Two, M4 or two 3.5-dia. hole
660.3 78 max. 35.5
39 max. Six, M3 x 8
4 24.3
6
Note: 1. The internal connections diagram is for the MKS2(X)T@@-11. 2. The P7MF-06-D has polarity. Be careful to wire with the correct polarity.
310.2
General Purpose Power Relays
MKS-X
7
Hold-down Clip
PYC-A2 One Set (Two Clips)
5 max.
42.8
4.5
1.2
4.5
Note: The minimum order for the PYC-A2 is ten clips.
Socket Mounting Height
P7M-06P
64
MK-S(X)
61
P7MF-06 P7MF-06-D
MK-S(X)
74
70
75
79
8
General Purpose Power Relays
MKS-X
Safety Precautions
Be sure to read the precautions and information common to all electromechanical relays, contained in the Technical User's Guide, "Electromechanical Relays, Technical Information" for correct use.
Precautions for Correct Use
Installation
* Models for DC loads (i.e., models with "X" in the model number) have permanent magnets built into the insulating block. If a permanent magnet or other magnetic body comes near the Relay, magnetic interference will occur with the built-in permanent magnet and the contact switching capacity will be decreased. * Models for AC loads do not contain a permanent magnet. * When mounting a P7MF-06(-D) Front-mounting Socket to a DIN Track, attach PFP-M End Plates on both sides of the Socket to prevent it from moving.
Operating Environment
Do not use the Relay in environments with combustible gas. Doing so may result in explosion due to arcing.
Storage
Models for DC Loads (i.e., models with "X" in the model number) are magnetized because they have a built-in magnet to deflect and extinguish the arc. Do not install the Relay near IC cards or other items that may be adversely affected by magnetism.
Usage
Use the Relay mounted in the P7M-06P or P7MF-06(-D) Socket.
Gang Mounting
Conditions for mounting multiple MKS-X relays on the same DIN rail.
Socket Relay Rated current of Relay Back-Connecting Socket Front-Connecting Socket
Test Button
* Turn OFF the power supply before operating the test button. Always return the test button to the original position after you use it. * Do not use the test button as a switch. * The durability of the test button is 100 operations minimum. The circuit can be checked using either of two modes.
Models for 10A DC Loads Models for 15A AC Loads

*
Test Button
DC specification: Blue AC specification: Red Normal
* Gang mounting of the Front-Mounting Sockets is not possible if the contact carry current exceeds 10A.Provide space on both the right and left sides of the Sockets. The mounting pitch is given in the following diagram.
Applied current (A)
20
15
10
5
Mode 1 (momentary)
Mode 2 (locked)
0 0 10 20 30 40 50 Mounting interval (mm)
Press the button for operation. (No tool is required.)
Lock the contacts by pressing down on the button and turning it.
Test Button Applications
Example: Checking operation of Relays and sequence circuits.
Mounting interval
Wiring
* The contact terminals on Models for DC Loads (i.e., models with "X" in the model number) have polarity. Wiring with incorrect polarity may result in inability to turn OFF the Relay or loss of functionality. * Be sure to check plarity when wiring DC coil MKS-X relays with built-in operation indicators.
General Purpose Power Relays
MKS-X
9
MEMO
10
General Purpose Power Relays
MKS-X
Omron Electronic Components, LLC
Terms and Conditions of Sales I. GENERAL 1. Definitions: The words used herein are defined as follows. (a) Terms: These terms and conditions (b) Seller: Omron Electronic Components LLC and its subsidiaries (c) Buyer: The buyer of Products, including any end user in section III through VI (d) Products: Products and/or services of Seller (e) Including: Including without limitation 2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments, invoices, purchase orders and other documents, whether electronic or in writing, relating to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's purchase order or other documents which are inconsistent with, or in addition to, these Terms. 3. Distributor: Any distributor shall inform its customer of the contents after and including section III of these Terms. II. SALES 1. Prices; Payment: All prices stated are current, subject to change without notice by Seller. Buyer agrees to pay the price in effect at the time the purchase order is accepted by Seller. Payments for Products received are due net 30 days unless otherwise stated in the invoice. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. 2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past due amounts owing to Seller. 3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 4. Orders: Seller will accept no order less than 200 U.S. dollars net billing. 5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer shall make remittance to Seller at the then current exchange rate most favorable to Seller; provided that if remittance is not made when due, Buyer will convert the amount to U.S. dollars at the then current exchange rate most favorable to Seller available during the period between the due date and the date remittance is actually made. 6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining any government approvals regarding the importation or sale of the Products. 7. Taxes: All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Seller or required to be collected directly or indirectly by Seller for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Seller. 8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller, Seller reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Seller may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Seller fully against all costs or expenses arising in connection therewith. 10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller: (a) All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Seller), at which point title to and all risk of loss of the Products shall pass from Seller to Buyer, provided that Seller shall retain a security interest in the Products until the full purchase price is paid by Buyer; (b) Delivery and shipping dates are estimates only; and (c) Seller will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products occurring before delivery to the carrier or any claim related to pricing or other charges must be presented in detail in writing to Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability: IT IS THE BUYER'S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER'S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E) SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT. Buyer acknowledges that it alone has determined that the Products will meet their requirements of the intended use in all cases. Buyer must know and observe all prohibitions of use applicable to the Product/s. 2. Use with Attention: The followings are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible use of any Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference.
(b) Use in consumer Products or any use in significant quantities. (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (d) Systems, machines, and equipment that could present a risk to life or property. 3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY SELLER. 5. Programmable Products: Seller shall not be responsible for the Buyer's programming of a programmable Product. IV. WARRANTY AND LIMITATION 1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Seller (or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES, NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. 2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an amount equal to the purchase price of the Product; provided that there shall be no liability for Seller or its affiliates unless Seller's analysis confirms that the Products were correctly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Seller before shipment. 3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. 4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. V. INFORMATION; ETC. 1. Intellectual Property: The intellectual property embodied in the Products is the exclusive property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way without the written permission of Seller. Buyer (at its own expense) shall indemnify and hold harmless Seller and defend or settle any action brought against Seller to the extent that it is based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Seller. All information and materials supplied by Seller to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 3. Performance Data: Performance data is provided as a guide in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. 4. Change In Specifications: Product specifications and descriptions may be changed at any time based on improvements or other reasons. It is Seller's practice to change part numbers when published ratings or features are changed, or when significant engineering changes are made. However, some specifications of the Product may be changed without any notice. 5. Errors And Omissions: The information on Seller's website or in other documentation has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses regarding (a) export of the Products or information provided by Seller; (b) sale of Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information. VI. MISCELLANEOUS 1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing between Buyer and Seller shall operate as a waiver of rights by Seller. 2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent. 3. Law: These Terms are governed by Illinois law (without regard to conflict of laws). Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any dispute hereunder. 4. Amendment: These Terms constitute the entire agreement between Buyer and Seller relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. 5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision.
General Purpose Power Relays
MKS-X
11
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iii) Use in consumer products or any use in significant quantities. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 3. Performance Data. Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to Seller's Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Seller representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. The information in this publication has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. 6. RoHS Compliance. Where indicated, our products currently comply, to the best of our knowledge as of the date of this publication, with the requirements of the European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information.
Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ELECTRONIC COMPONENTS LLC
55 E. Commerce Drive, Suite B Schaumburg, IL 60173
OMRON ON-LINE
Global - http://www.omron.com USA - http://www.components.omron.com
847-882-2288
Cat. No. J175-E-02 09/09 Specifications subject to change without notice Printed in USA
12
General Purpose Power Relays
MKS-X


▲Up To Search▲   

 
Price & Availability of MKS1XT-10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X